How to Control Electric Water Heater using Switches?

Controlling of Water Heater using Single Pole, Two Poles & Intermediate Switches?

In our electric water heater wiring series, we will be showing that how to control the water heater using single way, two way, three way and four-way (intermediate) switches.

How to Control Water heater using single way, two way, three way and four-way Intermediate Switches

Controlling of Water Heater using Single-Pole Switch

To control a non-continuous (non-simultaneous) water heater using a single way or one-way switch, we must use a 10 gauge wire size with a minimum 30 amp circuit breaker. In our case, we have connected the water heater directly to a 30 amperes single way switch which is protected by a 30 amp circuit breaker from the main distribution board. The down position of the switch is used to break the line supply to the water heater. In the case of 240V heater, a single line cut off is sufficient to switch off the water heater. Also, don’t forget to do the proper grounding to the switch and water heater.

Click image to enlarge

How to Control Electric Water Heater with Single Way Switch - One-way switch

Good to know:

Controlling of Water Heater using Double Pole Switch

A double pole switch can be also used to control the ON/OFF operation of electric water heaters. In our case of 240V water heater, we have used a 30 amp double pole switch protected by a 30 amp circuit breaker form the main supply panel.

This way, both lines (hot or phase) wires are turned off by switch. Only breaking a single line supply will work perfectly, but we are still able to use the double pole switch instead of single pole switch as it makes sure to turn the power off to the water heater. This way, the double pole acts as a safety switch as well.

Safety switches are required in tankless water heaters, HVAC (heating, ventilation, and air conditioning), commercial water heaters or when the main circuit breaker box is not within sight.

Good to know:

Controlling of Water Heater using DPST Switch

The following wiring diagram shows a DPST (Double Pole, Single Throw) switch rated for 120V to 277V and fed-up by 240V 2-pole breaker is used to wire and control a water heater. It clearly shows the common (dark screws) are connected to the 240V supply voltage via Hot 1 and Hot 2. The L1 and L2 (brass screws are directly connected to the water heater. Since it is a 240V circuit, hence no Neutral is needed.

Click image to enlarge

How to Control Water Heater using double-pole Switch

Finally, the ground wire is connected to both the DPST switch green screw and the terminal box of the water heater. This way, the ON and OFF operation will close or open both the sources i.e. Line 1 and Line 2.

Similarly, the following wiring diagram shows controlling of 240V non-continuous water heater thermostat and element using 20A double pole, single throw switch.

Click image to enlarge

230V & 240V AC Non-Continuous Dual Element 3.5kW Water Heater Thermostat Wiring

Controlling of Water Heater from Two Places using Two, 3-Way Switches

Using the following diagram, we can control an electric water heater from two different places, similar to the staircase wiring diagram where a single light bulb can be controlled from two places using three way switches.

In case of single phase 120V supply, the neutral is directly connected to the water heater where the hot wire (live or line) is connected to the common of a three way switch. Both 3-way switches are connected via traveler wires (blue) while the common of the second 3-way switch is connected to the water heater. A proper grounding and 30 A circuit breaker with 10 gauge wire should be used for 240V. In case of 120V, a 12 gauge wire should be used according to the rating. Only one live wire is enough to cut off the power supply through a 3-way switch. Overall, it is known as a 3-way circuit. Both switches and circuit breaker rating is 30 amperes.

Click image to enlarge

How to Control Water Heater from Two Places using Two, 3-Way Switches

Good to know:

A switch rated for:

Controlling of Water Heater from Three Places using Two, 3-Way & Four Way Switch

If we connect an intermediate (4-way) switch in between two 3-way switches in the above circuit, we will be able to ON/OFF the water heater from three different places as shown in below wiring diagram for 240V, 230V and 120V AC.

The rating of circuit breaker and all switches including three way and 4 way is 30 amp. You may use proper rated switches and breaker size for single phase 120V. Don’t forget to do proper earthing/grounding to the water heater and switches.

Click image to enlarge

Control Water Heater from 3 Places using 2, 3-Way Switches and 4-Way Switch (Intermediate Switch)

Good to Know:

Precautions

Warning & Precautions

  • Disconnect the power before replacing, repairing, troubleshooting, maintenance and installation electrical appliances and equipment.
  • Use the suitable voltage and ampere rating of switch with appropriate wire size and proper size of breaker according to the load rating.
  • Failure to do so can result in electrical shock, serious injury, fire or even death.
  • Perform a continuity test for the switch terminal before wiring and installation. Use 10 gauge wire for 240V and 12 Gauge for 120V in the above wiring tutorials. Follow the user manual guide or contact a licensed electrician for proper installation. All the above wiring diagrams are for non-simultaneous (non-contentious) heating elements and thermostat operation.
  • Red color illustrates the Line or Phase wire and Black color shows the Neutral Wire in the above figures. You may follow your regional wiring color codes i.e. IEC or NEC.
  • Please follow the manual instruction, local area codes or contact a licensed electrician for proper installation.